ORBIT CONTROLS
Three Phase Power Calibrator
Output voltage per phase : 6-260Vac
Voltage compliance current : min 30mA
Output Current per phase : 100mA - 10A
Current compliance voltage : min 2.5V
Current phase shift : 0 - 360°
Frequency : 40-400Hz in 0.001Hz steps
Phase adjustment : 0-360° in 1° steps
AC Power and Energy accuracy : 0.08%
Integral DC volt and ammeter
Full IEEE-488 GPIB control
Multifunction Calibrator
AC & DC Voltage range : 0 - 1000V
AC & DC Current range : 0 - 10A
AC frequency range : 40Hz - 20kHz
Current compliance voltage : 1.5 - 3.0V
Resistance range : 10W to 10MW
Capacitance range : 1nF to 10µF
AC power & energy : max 250V @ 10A
Frequency generator : 10Mhz TTL & 10kHz 10V Square wave
Temperature simulator TC, Ni and RTD
Full IEEE-488 GPIB control
Multifunction Calibrator
AC & DC Voltage range : 0 - 1000V
AC & DC Current range : 0 - 20A
AC voltage frequency : 20Hz - 50kHz
AC current frequency : 20Hz - 5kHz
Resistance range : 0W to 50MW
Capacitance range : 900pF to 50µF
AC power & energy : max 240V @ 10A
Frequency generator : 20Mhz TTL & 100kHz 10V Square wave
Temperature simulator TC, Ni and RTD
Full multi-meter functions
Full IEEE-488 GPIB & RS232 control
High Resistance Decade
Resistance range : 1MW to 12.221GW
Decade accuracy :
-1MW to 11MW @ 0.1%
-10MW to 110MW @ 0.2%
-100MW to 1.1GW @ 0.5%
-1GW to 12GW @ 1.0%
Voltage coefficient : ±1 to 2ppm/V
Applied voltage range : 700V to 5kV
Serial interface : RS232
Battery or mains supply
Precision Resistance Decade
Resistance range : 16W to 10kW
Resolution : 0.0001W
Temperature coefficient : < 1ppm/K
Accuracy : 0.005%
Temperature simulation : RTD & Ni
Accuracy : ±0.02°C
RS232 serial port
Battery & mains supply
Process Handheld Calibrator
Current (source/sink) : 0/4 to 20mA
Voltage range : 0 to 10V
Signal ramp/step generator
Multimeter functions : V / I / R
Accuracy : ± 0.01%
Sampling time : 1 per 2 seconds
Rechargeable battery : 4/5 hours continuous operation
Return to Lyons Instruments
The Claude Lyons Group
Brook Road, Waltham Cross, Herts, EN8 7LR, England
Tel: 01992 768888 Fax: 01992 788000
Site last updated: Wednesday, February 20th 2008
Claude Lyons Group
|
Claude Lyons online store
|
Energy Saving
|
Claude Lyons Voltage Stabilisers
|
Applications
|
Broadcast Applications
|
Energy Saving Applications
|
Medical Applications
|
Printing Applications
|
Railways Applications
|
Telecommunications Applications
|
Testing Applications
|
UPS
|
Voltage reduction compensation
|
Uninterruptible Power Supplies
|
Conditioning Products
|
Power Quality Management
|
Maintenance & Service
|
The Transformer & Electrical Company
|
Resistors
|
Variable Transformers
|
TEC Power Transformers, Inductors and Rectifiers
|
Lyons Instruments
|
Technical Notes from Claude Lyons
|
Voltage Stabilisation Techniques
|
Variable Transformers
|
Energy Saving & Equipment Life Prolongation
|
Claude Lyons Latest News
|
Claude Lyons Events Diary
|
Claude Lyons Literature
|
How To Find Claude Lyons
|
Contact Claude Lyons
|
Warranty/Feedback
|
About The Claude Lyons Group
|
Site Map
The Claude Lyons Group - Copyright © -
Valid HTML 4
|
Valid CSS